Rake Probe Diagnostics |
|
||
|
|||
|
|
|
The rake probe is a linear array of Langmuir tips to measure radial profiles of selected
parameters of the edge plasma in a single tokamak discharge. The presented design of the
probe head consists of 16 Langmuir tips spaced by 2.5 mm. This distance defines the spatial
resolution of the measurement. The tips are made of molybdenum wire of the diameter 0.6
mm. The length of the tip is l = 3.3 mm. |
|