High Voltage Power Supply

Model: HV 5000T

High Voltage Supplies

 

 

 

Click to enlarge

HV5000T is a stabilised high voltage supply ranging 0-5000V (optionally 1kV/ 2kV / 3kV/ 4kV) with current limiting, indication of output current and voltage, and current limiting status indicator (LED, relay).

Power Supply and Start
The device is fed by +230V (± 10%) DC power supply; high voltage (HV) is present on the output terminals only if the START button is in the switched-on position (locking button).

Current Limiting Feature
Current limiting status is detected and indicated by the device in two possible ways:
Option A (manufacturer setup)
Relay operates in a temporary mode, i.e. when current limiting is in use or not used relay contacts RLC ---- RL1 or RLC --- RL2 close or open, respectively. At the same time REL indicator lights up and voltage appears (+24V against GND) on terminal P (disappearing from terminal N at the same time). After the current limiting is no longer used all the above described outputs return to their state as before the current limiting. AUX indicator lights on and remains lighted even after current limiting. This serves as a long-term indication of the fact that current limiting had been used (the feature can be used for instance for long-term observation etc.). AUX can be turned off by pressing the RES button (or it can be turned off externally by closing a contact between the RES and +5V terminals).

Option B (internal setup needs to be changed - jumper). This option is opposite to the previous one, i.e.:
Relay operates in a permanent mode, i.e. when current limit is in operation or out of operation relay contacts RLC ---- RL1 or RLC --- RL2 close or open, respectively. At the same time REL indicator lights up and voltage appears (+24V against GND) on terminal P (disappearing from terminal N at the same time). After the current limit is no longer in operation, the relay remains closed until it is reset by pushing a button or by applying external signal. AUX indicator lights up only when current limiting is in use and switches off immediately after the current limiting is no longer in use.

 