Elektro-optický trigrovací systém TRIG 2000

The TRIG 2000 sys­tem is designed to con­vert input elect­ric sig­nals into opti­cal sig­nals, dis­tri­bu­te them and con­vert them back into elect­ric sig­nals. Two lines are avai­la­ble (mili­se­cond tri­g­ger chan­nel and micro­se­cond tri­g­ger chan­nel). More­o­ver, the out­put sig­nals can be dela­yed. Finally, the delay between the micro­se­cond elect­ric sig­nal and opti­cal sync sig­nal (laser pul­se) is mea­su­red and indi­ca­ted. Input tri­g­ger sig­nals are coun­ted and indi­ca­ted. All devi­ces ope­ra­te in bat­te­ry mode during mea­su­re­ment, this mode is tri­g­ge­red exter­nally.

Input box

Input sig­nal 1

200 V

Durati­on of input sig­nal 1

typ. 1 ms

Input sig­nal 2

200 V

Durati­on of input sig­nal 2

typ. 1 µs

Wave­len­gth of opti­cal out­put

1310 nm

Opti­cal out­put power

1 mW

No of dis­tri­bu­ti­on out­puts

3

Input con­nec­tors

BNC

Opti­cal con­nec­tors

FC / PC

Power

230 VAC, 50/60 Hz

Power line sys­tem

1/N/PE

Out­put box

Durati­on of input sig­nal 1

typ. 1 ms

Durati­on of input sig­nal 2

typ. 1 µs

Wave­len­gth of opti­cal out­put

1310 nm

Opti­cal out­put power

1 mW

Input con­nec­tors

FC/PC and FC/APC (laser)

Out­put con­nec­tors

BNC

Out­put vol­tage

TTL / +5V / 50 Ω

Laser input sig­nal

1310 nm / 300 ps

Power

230 VAC, 50/60 Hz

Power line sys­tem

1/N/PE

Dimensi­on

19″ × 1U × 250 mm (483 × 44 × 250 mm)

Wei­ght

3 kg